Reducing Heat Pump Noise

Quiet operation with the Silentbox

If your heat pump or air conditioning unit is too loud, the Silentbox offers a simple and effective way to reduce noise. It helps to significantly lower sound levels without affecting the performance of your equipment.

 

As heat pumps and cooling units become more common in residential areas, noise reduction is no longer just a nice-to-have — in many cases, it's a necessity to ensure peace for you and your neighbors.

Quiet operation with the Silentbox

Comfort Without Compromise

Reliable noise control with easy installation

The Silentbox offers strong noise reduction while maintaining the full technical performance of your heat pump. Installation is quick and non-invasive — no modifications to the unit are required. The result is a quieter, more comfortable environment for everyone nearby.

 

Thanks to adjustable air flow direction, the Silentbox is suitable for various installation scenarios. Condensation drains easily through the open sections in the base frame.

Heat Pump Enclosure – Silentbox

Simple look, impressive results

The enclosure is made of painted steel (RAL 9010) and filled with high-quality sound insulation. All materials are designed to withstand weather exposure and meet fire resistance class B according to EN 13501-1.

 

The base frame is made of galvanized sheet metal. The intake and exhaust air zones are separated by a flexible membrane to prevent air mixing during operation and ensure stable performance.

Acoustic attenuation D -15 dB

Peace in the house and garden, the pump remains unobtrusive to neighbors and the surroundings.

Protection for the heat pump

The cover protects the pump from rain, snow, UV radiation, and dirt. The result is a longer lifespan and lower maintenance costs.

Increase in property value

Adds value to the property – appears well thought-out and professional.

Aesthetic enhancement of the house

Conceals the technical equipment, improves the overall appearance of the house, and makes a strong impression.

Easy installation

Minimal construction work.

by installing Silentbox

in the Czech Republic, Slovakia, Austria, Germany, Poland, France, the Netherlands, Belgium, Switzerland, and Italy.

Rating and designing

To achieve maximum effect

The noise cover for the heat pump or air conditioning unit is designed with respect to its size, cooling air need, and fan pressure reserve.

Price from €930

List price excluding delivery and installation.

Technical data

Size of the silencing cover and attenuation X YT YS Z A B weight
(kg)
  instalation on floor instalation wall        
Alfa S 1560 1115 1175 790 940 1015 128
Alfa SU 1720 1115 1175 790 940 1015 179
Beta S 1950 1305 1365 1030 1170 1205 178
Beta S plus 1950 1305 --- 1250 1170 1205 203
Beta SU 2250 1305 1365 1030 1170 1205 229
Beta SU plus 2250 1305 --- 1250 1170 1205 254
Gama S 2150 1625 1685 1180 1170 1525 220
Gama S plus 2150 1625 --- 1400 1170 1525 250
Gama SU 2550 1625 1685 1180 1170 1525 296
Gama SU plus 2550 1625 --- 1400 1170 1525 326
Delta S 2910 1650 1745 1680 1200 1610 278
Delta S plux 2910 1650 --- 1900 1200 1610 313
Technical data

Technical data

Size of the silencing cover
and attenuation
Max. size of heat pump or cooling unit w x h x d Air flow Q / cover pressure loss m3/h | Pa
Alfa S 800 x 1035 x 350 mm 1250 m3/h | 15 Pa 1600 m3/h | 25 Pa 2000 m3/h | 40 Pa 
Alfa SU 800 x 1035 x 350 mm 1500 m3/h | 15 Pa 1900 m3/h | 25 Pa 2400 m3/h | 40 Pa 
Beta S 1030 x 1225 x 430 mm 2100 m3/h | 15 Pa 2700 m3/h | 25 Pa 3400 m3/h | 40 Pa 
Beta S plus 1030 x 1225 x 650 mm 2100 m3/h | 15 Pa 2700 m3/h | 25 Pa 3400 m3/h | 40 Pa 
Beta SU 1030 x 1225 x 430 mm 2500 m3/h | 15 Pa 3250 m3/h | 25 Pa 4100 m3/h | 40 Pa 
Beta SU plus 1030 x 1225 x 650 mm 2500 m3/h | 15 Pa 3250 m3/h | 25 Pa 4100 m3/h | 40 Pa 
Gama S 1030 x 1545 x 430 mm 3450 m3/h | 15 Pa 4400 m3/h | 25 Pa 5550 m3/h | 40 Pa 
Gama S plus 1030 x 1545 x 650 mm 3450 m3/h | 15 Pa 4400 m3/h | 25 Pa 5550 m3/h | 40 Pa 
Gama SU 1030 x 1545 x 430 mm 4250 m3/h | 15 Pa 5450 m3/h | 25 Pa 6850 m3/h | 40 Pa 
Gama SU plus 1030 x 1545 x 650 mm 4250 m3/h | 15 Pa 5450 m3/h | 25 Pa 6850 m3/h | 40 Pa 
Delta S 1030 x 1650 x 430 mm 6200 m3/h | 15 Pa 8100 m3/h | 25 Pa 10300 m3/h | 40 Pa 
Delta S plux 1030 x 1650 x 650 mm 6200 m3/h | 15 Pa 8100 m3/h | 25 Pa 10300 m3/h | 40 Pa 

Ground installation

Installing the heat pump cover on the ground ensures stable and secure anchoring without the need to alter the building façade – ideal for easy maintenance and service access. It also allows flexible placement in the garden or on a paved area according to the property layout.

Wall installation

Mounting the cover on the wall saves ground space, which is advantageous in smaller areas or where access is limited. The elevated position also improves airflow around the unit, supporting efficient operation.

Photos of installations

from our customers

Silent / Supersilent

In addition, the cover size depends on type and size of the unit, and last but not least on volume of the ventilation air. The pressure drop of the Silent / Supersilent noise covers depends on the unit air volume. For pressure loss, refer to the technical data table.

Considering the unit output, always consult supplier or manufacturer of the heat pump or the cooling unit for the pressure reserve of the fans. For non-standard solutions, contacting the technical team of Stavoklima or an authorized technical office is recommended. Noise control Covers are not intended for devices using refrigerant R290.

Catalogue

For download

Do you like SilentBox?

We will be happy to supply it to you.

Use our ACUCALC application or contact us by phone or e-mail to design the noise cover for heat pump or air conditioning unit.